Design of electrical connection Screw connection
Cable section
- Min. Cable section 0,75
- Max. Cable section 2.5
Mechanical life 20.000.000 operations
Switching frequency max. 5000 /h
notice All indications about the cable section are including the conductor ferrules.
Design of actuating element Roller plunger
Actuating force min. 9 N
Bounce duration in accordance with actuating speed
Switchover time in accordance with actuating speed
Positive break force 19 N
Actuating speed with actuating angle 30° to switch axis
- Min. Actuating speed 120 mm/min
- Max. Actuating speed 1 m/s
Electrical data:
Design of control element Opener (NC)
Switching principle Creep circuit element
- positive break NC contact
Number of auxiliary contacts 0
Number of safety contacts 2
Rated impulse withstand voltage Uimp 6 kV
Rated insulation voltage Ui 500 V
Thermal test current Ithe 10 A
Utilisation category AC-15: 230 V / 4 A,
DC-13: 24 V / 1 A
Required rated short-circuit current 1000 A
Max. fuse rating 6 A gG D-fuse
Dimensions:
Dimensions of the sensor
- Width of sensor 30 mm
- Height of sensor 86 mm
- Length of sensor 30 mm