Shopping security
The Allen-Bradley 1771-OAN, also cataloged as the 1771-OAN Digital AC Output Module, operates as a dedicated hardware component for binary AC load switching within PLC 5 platforms. The assembly converts logic commands received across the chassis backplane into physical state changes for 32 independent AC outputs, utilizing triac switching circuits arranged in four isolated groups of eight channels.
| Parameter | Specification |
| Model | 1771-OAN |
| Brand | Allen-Bradley / Rockwell Automation |
| Origin | USA |
| Weight | 1.05 kg (2.31 lbs) |
| Dimensions | Standard 1771 single-slot module dimensions |
| Operating Temp | 0 to +60 deg C |
| Power Consumption | 5 VDC backplane current consumption at 800 mA |
| Number of Outputs | 32 outputs (4 groups of 8 channels) |
| Voltage Category | 85-264 VAC (Nominal 120 / 240 VAC) |
| Max Continuous Current Per Point | 1.0 A at 30 deg C / 0.3 A at 60 deg C |
| Max Continuous Current Per Group | 2.0 A at 30 deg C / 0.6 A at 60 deg C |
| Max Continuous Current Per Module | 8.0 A at 30 deg C / 2.4 A at 60 deg C |
| Signal Delay (Off to On) | 1 ms maximum |
| Signal Delay (On to Off) | 9.3 ms at 60 Hz / 11 ms at 50 Hz |
| Circuit Board Protection | Conformal coat application |
| Required Field Interface | 1771-WH wiring arm |
The electronic architecture interfaces with the 1771 chassis infrastructure to execute high-density scaling of discrete AC points across a single slot. Data transfer occurs via BCD or Natural Binary data formats, syncing directly with the main processor scan to maintain backplane bus communication velocity parameters. The control logic relies on native firmware flash compatibility paths across the PLC-5 processor family, allowing the 800 mA backplane current load to remain constant without fluctuating during multi-channel execution.
Q: How does the maximum continuous current rating adjust to ambient temperature increases within the local electrical enclosure?
A: The module operates under a strict thermal derating curve. At 30 deg C, each independent point allows up to 1.0 A continuous load, which decreases to 0.3 A per point when the ambient environment reaches 60 deg C to protect the triac junctions from thermal runaway.
Q: Can this module be extracted from the 1771 rack infrastructure while the backplane bus is actively powered?
A: No. The 1771 I/O architecture does not support live removal or insertion under power. Removing the component during active backplane communication can generate electrical noise, disrupt processor execution, and cause terminal damage to the backplane connectors.
Ships within 48 hours · Estimated delivery Jun 22 - Jun 27
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order