home > HIMA F 3334 Brand New 24VDC 2A Safety Output Unit > HIMA F 3334 Brand New 24VDC 2A Safety Output Unit
download picture
HIMA F 3334 Brand New 24VDC 2A Safety Output UnitProduct Overview The HIMA F3334 serves as a high integrity, 4 fold digital output module designed for critical safety instrumented systems (SIS) and programmable electronic systems (PES). This hardware configuration provides four independent fail safe channels to actuate field level final control elements, including safety valves, solenoids, and indicators. By incorporating strict dual channel internal processing, this module drives safety critical
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Overview

The HIMA F3334 serves as a high-integrity, 4-fold digital output module designed for critical safety instrumented systems (SIS) and programmable electronic systems (PES). This hardware configuration provides four independent fail-safe channels to actuate field-level final control elements, including safety valves, solenoids, and indicators. By incorporating strict dual-channel internal processing, this module drives safety-critical loops in emergency shutdown (ESD), fire and gas (F&G), and high-availability process control setups.

Technical Specifications

  • Manufacturer: HIMA Paul Hildebrandt GmbH + Co KG

  • Part Number: F3334

  • Product Category: PLC Digital Output Module

  • Safety Certification Level: IEC 61508 SIL3 / IEC 61511

  • Channel Count: 4 independent fail-safe output channels

  • Nominal Supply Voltage: 24 VDC

  • Rated Switching Current: 2.0 Amperes per channel

  • Maximum Power Consumption: 5.0 Watts

  • Maximum Internal Voltage Drop: 2.0 V at 2.0 Ampere full load

  • Admissible Maximum Line Resistance: 3.6 Ohms

  • Undervoltage Trip Threshold: Less than or equal to 16.0 VDC

  • Maximum Channel Leakage Current: 550 Microamperes

  • Space Requirement: 4 TE backplane width slot

  • Physical Dimensions: 2.1 cm x 19.0 cm x 12.8 cm

  • Net Component Weight: 0.24 KG

  • Country of Origin: Germany

  • Hardware Condition: 100% Brand New Original Stock

Engineering Advantages

Comprehensive Fault Isolation and Self-Diagnostics

The internal architecture continuously traces line integrity, monitoring each output path for short circuits, line breaks, and undervoltage faults. When the module identifies an abnormal state or drops below the 16 VDC threshold, it trips the affected channel cleanly while maintaining operation across the remaining loops. This localized fault containment isolates field failures before they corrupt the central processing bus.

Inductive and Resistive Heavy-Duty Actuation

Each of the four outputs switches up to 2.0 Amperes without requiring interposing relays. The robust internal solid-state design absorbs high inductive kickback from large solenoid valves and emergency trip relays. This direct-drive capability simplifies marshaling cabinet wiring, minimizes total component count, and eliminates mechanical contact wear.

Thermal Resilience in Packed Marshaling Enclosures

The compact 4 TE form factor optimizes chassis space, allowing system builders to group multiple output zones together. The efficient 5-Watt power distribution minimizes heat dissipation during continuous full-load deployment. This low thermal profile protects nearby components from heat aging and eliminates the need for active climate control within typical -20 to +60 degrees Celsius operational footprints.

FAQs

  • Does this module require an external freewheeling diode for inductive loads? No. The F3334 integrates internal surge protection that suppresses inductive voltage spikes when driving solenoids or magnetic contactors. Engineers can wire standard inductive loads directly to the output terminals without external suppressing components.

  • How does the module handle a control line break scenario? The embedded diagnostics send a tiny supervisory current through the loop during the off-state. If a field wire snaps, the module detects the drop in leakage current, logs a line break fault in the central safety system log, and illuminates the corresponding front panel diagnostic LED.

  • Can I parallel multiple channels on the F3334 to handle loads higher than 2 Amperes? No. Paralleling channels to increase current capacity violates the SIL3 safety compliance parameters. You must limit the continuous load of each discrete loop to a maximum of 2.0 Amperes to prevent thermal overload and preserve fail-safe switching execution.

HIMA F 3334 Brand New 24VDC 2A Safety Output Unit

Item no : 89896769548
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 22 - Jun 27

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches