Shopping security
The Allen-Bradley 1783-MS06T functions as a high-performance Layer 2 managed industrial Ethernet switch within the Stratix 8000 network infrastructure family. This network module provides 6 fast copper RJ45 ports that facilitate wire-speed switching, VLAN segmentation, and IGMP snooping directly on the factory floor. Designed to embed seamlessly into modern EtherNet/IP architectures, the switch utilizes Common Industrial Protocol (CIP) integration to pass real-time diagnostics and status data straight to Logix controllers.
We deliver this product as a 100% Brand New, original factory-sealed unit in its native factory packing. Each shipment carries a 12-month comprehensive factory warranty, ensuring uncompromised internal circuitry, unblemished connector ports, and authentic embedded firmware ready for secure machine-level deployment.
| Parameter | Specification Data |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Product Line | Stratix 8000 / Stratix 5700 Series |
| Model Number | 1783-MS06T |
| Condition | 100% Brand New Original Factory Sealed |
| Switch Architecture | Fully Managed Layer 2 Industrial Switch |
| Total Copper Port Count | 6 x RJ45 Ports (10/100/1000 Mbps Auto-Negotiation) |
| Power Input Requirements | 2 A maximum at 18 to 60V DC, Class 2 / SELV |
| Maximum Power Consumption | 15.1 Watts (Expansion module load excluded) |
| Power and Thermal Dissipation | 15.1 Watts maximum |
| Maximum Inrush Current | 2.0 Amps |
| Alarm Relay Contact Rating | 1 A maximum at 30V DC, Class 2 / SELV |
| Continuous Isolation Voltage | 75V continuous (basic insulation type) |
| Isolation Boundaries | Power to ground, power to network, power to alarm |
| Ethernet Cable Requirements | RJ45 connector, Category 5e minimum (2 or 4 pair) |
| Power and Alarm Wire Size | 0.5 to 0.8 mm2 (20 to 18 AWG) solid or stranded copper |
| Ground Conductor Wire Size | 3.3 to 5.3 mm2 (12 to 10 AWG) solid or stranded copper |
| Terminal Screw Torque | Power and Alarm: 0.23 N-m; Ground: 0.96 N-m |
| Redundancy Protocol Support | Device Level Ring (DLR), RSTP (IEEE 802.1w) |
| Industrial Integration | Studio 5000 Add-On Profile (AOP), CIP Integration |
| Surrounding Air Temperature | Maximum 60 degrees Celsius (140 degrees Fahrenheit) |
| Physical Enclosure Rating | None (Open-style industrial module) |
| Hazardous Location Temperature Code | North American T4 / ATEX T4 |
Streamline Control Logic Integration: Standard commercial switches require separate external software utilities to monitor port status. The 1783-MS06T utilizes full CIP integration, allowing automation engineers to configure, manage, and retrieve network diagnostics directly inside Studio 5000 Logix Designer using standard Add-On Profiles (AOP).
Enforce Zero-Downtime Ring Redundancy: Cable cuts disable standard star networks instantly. This managed switch executes Device Level Ring (DLR) protocols to create a fault-tolerant network ring, redirecting data traffic within milliseconds if a physical network link suffers damage.
Filter Destructive Multicast Traffic: Unmanaged Ethernet networks flood all ports with multicast I/O traffic, choking downstream devices. The 1783-MS06T activates IGMP snooping to direct multicast data streams strictly to the specific target nodes that request them, optimizing backplane bandwidth.
Isolate Electrical Ground Transients: Industrial power systems generate heavy voltage spikes and ground shifts. This module implements a 75V continuous basic insulation barrier that separates incoming power channels from the ground framework and network paths, stopping electrical noise before it corrupts communication lines.
What mounting style does the 1783-MS06T open-style switch require?
The 1783-MS06T features a compact, open-style industrial housing designed for direct installation onto standard 35 mm DIN rails inside a protective, enclosed control panel. Because it carries an open-style rating, you must shield the switch from external liquid spray, dust, and conductive contaminants.
How do technicians wire the power input and alarm relay terminals safely?
Use solid or stranded copper wire rated for 90 degrees Celsius or higher, with a cross-section between 0.5 and 0.8 mm2 (20 to 18 AWG). Strip the wire insulation back a maximum of 1.2 mm, insert the copper leads into the screw terminals, and tighten the terminal screws to a torque specification of exactly 0.23 N-m (2.0 in-lb).
Does this switch provide isolation between individual Ethernet ports?
No. The 75V continuous basic insulation separates the main DC power circuit from the ground line, alarm terminals, and the collective network channels. However, the 6 individual RJ45 Ethernet communication ports share a common ground reference, meaning no electrical isolation exists between individual network ports.
Ships within 48 hours · Estimated delivery Jun 23 - Jun 28
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order